App Header Failed

Discussion to talk about software related topics only.
Post Reply
SeeCwriter
Posts: 626
Joined: Mon May 12, 2008 10:55 am

App Header Failed

Post by SeeCwriter »

On a brand new MOD54415-200IR module, when I power it up the serial port spits out:

Code: Select all

App Header Failed
No Valid app

App Header Failed

NetBurner MCF5441x SPI Boot Monitor V1.06 Feb 28 2020 18:20:21
HELP for help
Using the serial terminal MTTTY, I uploaded MOD5441x-FactoryApp_APP.s19 (from v2.9.5) and when it finished, the terminal output was:

Code: Select all

Starting address = 40000490
S Record End detected
And then nothing. A reboot does the same thing.

Is there any way to recover this module?
User avatar
TomNB
Posts: 580
Joined: Tue May 10, 2016 8:22 am

Re: App Header Failed

Post by TomNB »

Yes, have you tried the shorting jumper recovery procedure? https://www.netburner.com/NBDocs/Develo ... overy.html
SeeCwriter
Posts: 626
Joined: Mon May 12, 2008 10:55 am

Re: App Header Failed

Post by SeeCwriter »

Yes, I tried the shorting jumper. It didn't help. I have two modules in this state. Both are new. The serial output of the first one is what I put in my first post. Shorting jumper TP1 during bootup produces the same messages as above. It doesn't appear that the Alternate Boot Monitor is started.
The second module has a higher rev monitor so its output is a little different. On bootup with TP1 shorted the output is:

Code: Select all

Boot overide Jumper Installed
    doing alternate boot
Config record corrupt
Configured IP= 0.0.0.0
Configured Mask= 255.255.255.0
MAC Address= 00:00:00:00:00:00
Welcome to the Netburner Alternate Boot Monitor Command Program

Netburner MCF5441x Alternate Image Monitor V1.11 July 17 2020 12:22:49