Search found 4 matches
- Mon Nov 05, 2012 3:27 am
- Forum: NetBurner's Eclipse IDE
- Topic: itoa() into MOD5213
- Replies: 1
- Views: 3234
Re: itoa() into MOD5213
This code works: /* itoa: convert n to characters in s */ void itoa(int n, char s[]) { int i, sign; if ((sign = n) < 0) /* record sign */ n = -n; /* make n positive */ i = 0; do { /* generate digits in reverse order */ s[i++] = n % 10 + '0'; /* get next digit */ } while ((n /= 10) > 0); /* delete it...
- Tue Oct 30, 2012 12:46 pm
- Forum: NetBurner's Eclipse IDE
- Topic: itoa() into MOD5213
- Replies: 1
- Views: 3234
itoa() into MOD5213
Hi, I'm trying to use itoa() into a MOD5213 project but the compiler doesn't recognize it. The manual says that itoa() needs system.h and utils.h found in C:\Nburn\include but I only have inlcuded into my project C:\Nburn\include_nn and system.h and utils.h doesn't contain itoa() function. Is it pos...
- Tue Oct 30, 2012 9:58 am
- Forum: NetBurner Software
- Topic: How to communicate MOD5270 and MOD5213
- Replies: 2
- Views: 2274
Re: How to communicate MOD5270 and MOD5213
Thanks!
pbreed wrote:I2C will work.
Async Serial communications will work. ie serial port
If you use a Mod5238 Mod5282, Mod54415 or Nano54415 you can communicate with the mod5213 via Can.
About the only comm channel that will not work is SPI.
- Mon Oct 29, 2012 8:47 am
- Forum: NetBurner Software
- Topic: How to communicate MOD5270 and MOD5213
- Replies: 2
- Views: 2274
How to communicate MOD5270 and MOD5213
Hello,
I neeed to communicate MOD5270 with MOD5213
is it possible if they only support master mode?
Thanks,
Alejandro
I neeed to communicate MOD5270 with MOD5213
is it possible if they only support master mode?